1104LD | 2014 | 3014 | 5014 | 3104 | 5104 | 5104V | |||||||
Specifications |
|||||||||||||
Size Range | 0.10 - 1.0 μm | 0.2 - 2μm | 0.3 - 25μm | 0.5 - 25μm | 0.3 - 25μm | 0.5 - 25μm | |||||||
Channel Sizes | Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 μm | Standard: 0.2, 0.3μm Standard: 0.2, 0.5μm Optional: 0.2, 0.3, 0.5, 1.0μm Optional: 0.2, 0.3, 0.5, 2.0μm |
Standard: 0.3, 0.5μm Standard: 0.3, 1.0μm Standard: 0.3, 3.0μm Optional: 0.3, 0.5, 1.0, 5.0μm |
Standard: 0.5, 5.0μm Optional: 0.5, 1.0, 5.0, 10.0μm Optional: 0.5, 5.0, 10.0, 25.0μm |
Standard: 0.3, 0.5μm Optional: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 5.0μm; Optional: 0.3, 0.5, 5.0, 10.0μm |
Standard: 0.5, 5.0μm; 0.5, 10.0μm Optional: 0.5, 1.0, 5.0, 10.0μm; 0.5, 5.0, 10.0, 25.0μm |
|||||||
Flow Rate | 1.0 CFM (28.3 LPM) | 0.1 CFM (2.83 LPM) | 1.0 CFM (28.3 LPM) | ||||||||||
Laser Source | Laser Diode | ||||||||||||
Zero Count Level | < 1 Count / 5 minutes (meets specifications of JIS B 9921 and reporting requirements of ISO 21501-4 Annex C) | ||||||||||||
Concentration Limits | 1,000,000 particles /ft3 (34,300,000/m3 ) @ 10% coincidence loss | 4,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms | 1,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms | ||||||||||
Calibration | NIST Traceable ISO 21501-4 Compliant and Accredited ISO 17025 | ||||||||||||
Vacuum Requirements | External Vacuum >18” (45.72 cm) of Hg | ||||||||||||
Air Flow | Internally Monitored | ||||||||||||
Communication Modes | Serial - 485 Modbus RJ45 | ||||||||||||
LED Indicators | Power, Flow, Service, Sampling | ||||||||||||
Data Storage | Rotating Buffer, 2000 Records | ||||||||||||
Supporting Software | LMS XChange, Lighthouse Monitoring System; LMS Express; Express RT; LMSNet | ||||||||||||
Environmental Sensors | - | (Optional) Temperature/Relative Humidity Probe 32 - 122F (0-50C)+/-1F (0.5C); 0 - 100% RH +/-2% | - | ||||||||||
Connector | RJ45 | Industrial RJ45 | |||||||||||
Power | 24 VDC | ||||||||||||
Dimensions | 10.5” (w) x 7.65” (h) x 3.35” (d) [26.67 x 19.43 x 8.51 cm] | 1.7”(l) x 4.2”(w) x 3”(h) [4.3 x 10.7 x 7.6 cm] | 1.7"(l) x 4.2"(w) x 3"(h) [4.3 x 10.7 x 7.6 cm] | 1.7”(l)x4.2”(w)x3”(h) [4.3x10.7x7.6cm] | 5.42” (l) x 2.14” (w) x 3.58” (h), [13.76 cm (l) x 5.43 cm (w) x 9.09 cm (h)] | ||||||||
Environmental Conditions |
|||||||||||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | ||||||||||||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Using state-of-the-art Long Life Laser Diode technology, the Lighthouse Remote 1104LD is an industry first- a laser diode-based remote particle counter with a sensitivity of 0.10 micron at a high flow rate of 1.0 CFM (28.3 LPM) that uses an optics and photodiode system designed to reduce or eliminate the temperature issues associated with high power laser diode sensors. Designed with reliability and quality in mind, the Remote 1104LD features our long-life laser diode technology that provides higher concentration limits, a better signal-to-noise ratio, and requires less routine maintenance than conventional HeNe laser-based particle counters. The Remote 1104LD supplies continuous real-time data at a cost-effective price per point. Very simple to integrate with large facility monitoring and management systems, the Remote 1104LD can transfer up to 8 channels of simultaneous particle count data via RS-485 MODBUS.
Key Features: