Search

Remote LPC 0.3 micron (MODBUS Output)

Technical Details

  LPC 0.1 μm (MODBUS) LPC 0.1 µm (4-20mA) LPC 0.2 μm (MODBUS) LPC 0.2 μm (4-20mA) LPC 0.3 μm (MODBUS) LPC 0.3 μm (4-20mA) LPC 0.5 μm (MODBUS) LPC 0.5 μm (4-20mA)

Specifications

Size Range 0.1 – 0.5 µm 0.1 – 0.5 µm 0.2 – 2.0 µm 0.2 –2.0 µm 0.3 – 3.0 µm 0.3 – 3.0 µm 0.5 – 100.0 µm 0.5 – 100.0 µm
Channel Sizes Standard: 0.1, 0.2, 0.3, 0.5 µm Standard: 0.1, 0.2μm;
Optional: 0.1, 0.3µm; 0.1, 0.5µm
Standard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μm Standard: 0.2, 0.3μm
Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μm
Standard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μm Standard: 0.3, 0.5μm
Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm
Standard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μm Standard: 0.5, 1.0μm
Optional: 0.5, 2.0μm; 0.5, 5.0μm
Laser Source Laser Diode
Flow Rate 100ml/min
Calibration NIST Traceable
Data Storage Rotating Buffer, 2000 Records - Rotating Buffer, 2000 Records - Rotating Buffer, 2000 Records - Rotating Buffer, 2000 Records -
Communication Modes RS-232 via RJ45 to PC, RS485/Modbus RS-232 via RJ45 to PC, 4-20mA RS-232 via RJ45 to PC, RS485/Modbus RS-232 via RJ45 to PC, 4-20mA RS-232 via RJ45 to PC, RS485/Modbus RS-232 via RJ45 to PC, 4-20mA RS-232 via RJ45 to PC, RS485/Modbus RS-232 via RJ45 to PC, 4-20mA
LED Indicators Power, Service, Sampling Power and Service Power, Service, Sampling Power, Service Power, Service, Sampling Power, Service, Sampling Power, Service, Sampling Power, Service, Sampling
Supporting Software LMS Express, Express RT and RT+, LMSNet
Concentration Limit 64,000 counts/ml @ 5% Coincidence Error 4,000 counts/ml @ 5% Coincidence Error
External Alarm Output Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp
Enclosure Stainless Steel
Sample Inlet/Outlet Connection 1/4" Flaretek™
Sample Temperature 32 - 302°F (0 – 150 °C)
Sample Pressure 150 PSI
Wetted Surface Materials Quartz, PTFE, PFA
Power 24V DC
Dimensions 5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]
Weight 3.5 lbs (1.58 kg)

Environmental Conditions

Operating 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Accessories

Included Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning Brush Operating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing. Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution
Optional Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet software Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket.

Get a Quote

GET A QUOTE

First Name (*)
Last Name (*)
Company Name (*)
Email (*)
Phone (*)
Address (*)
Country (*)
Primary Industry (*)
Message (*)
(*) Required Fields

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.3μm (Modbus Output) for continuous trouble-free operation.

With a minimum sensitivity range of 0.3 μm and a flow rate of 100 mL/min, the Remote Liquid Particle Counter 0.3 μm provides real-time continuous data collection at a cost-effective price per point.

This compact liquid particle counter provides versatile mounting options and can be installed where space is at a premium.

The Remote Liquid Particle Counter 0.3μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.

Features:

  • 0.3– 3.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 4 channels of simultaneous data
  • RS-485 Modbus Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Instrument Files

Title
Download
Datasheet – Remote LPC 0.1μm, 0.2μm, 0.3μm, 0.5μm
Download
Operating Manual – Remote LPC 0.1μm, 0.2μm, 0.3μm, 0.5μm
Download

Related Products