Remote LPC 0.1 micron (MODBUS Output)
• 0.1 – 1.0 μm particle size ranges
• 100 mL/min flow Rate
LPC 0.1 μm (MODBUS) | LPC 0.1 µm (4-20mA) | LPC 0.2 μm (MODBUS) | LPC 0.2 μm (4-20mA) | LPC 0.3 μm (MODBUS) | LPC 0.3 μm (4-20mA) | LPC 0.5 μm (MODBUS) | LPC 0.5 μm (4-20mA) | |
Specifications |
||||||||
Size Range | 0.1 – 0.5 µm | 0.1 – 0.5 µm | 0.2 – 2.0 µm | 0.2 –2.0 µm | 0.3 – 3.0 µm | 0.3 – 3.0 µm | 0.5 – 100.0 µm | 0.5 – 100.0 µm |
Channel Sizes | Standard: 0.1, 0.2, 0.3, 0.5 µm | Standard: 0.1, 0.2μm; Optional: 0.1, 0.3µm; 0.1, 0.5µm |
Standard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μm | Standard: 0.2, 0.3μm Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μm |
Standard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μm | Standard: 0.3, 0.5μm Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm |
Standard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μm | Standard: 0.5, 1.0μm Optional: 0.5, 2.0μm; 0.5, 5.0μm |
Laser Source | Laser Diode | |||||||
Flow Rate | 100ml/min | |||||||
Calibration | NIST Traceable | |||||||
Data Storage | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - |
Communication Modes | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA |
LED Indicators | Power, Service, Sampling | Power and Service | Power, Service, Sampling | Power, Service | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling |
Supporting Software | LMS Express, Express RT and RT+, LMSNet | |||||||
Concentration Limit | 64,000 counts/ml @ 5% Coincidence Error | 4,000 counts/ml @ 5% Coincidence Error | ||||||
External Alarm Output | Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp | |||||||
Enclosure | Stainless Steel | |||||||
Sample Inlet/Outlet Connection | 1/4" Flaretek™ | |||||||
Sample Temperature | 32 - 302°F (0 – 150 °C) | |||||||
Sample Pressure | 150 PSI | |||||||
Wetted Surface Materials | Quartz, PTFE, PFA | |||||||
Power | 24V DC | |||||||
Dimensions | 5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm] | |||||||
Weight | 3.5 lbs (1.58 kg) | |||||||
Environmental Conditions |
||||||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | |||||||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing | |||||||
Accessories |
||||||||
Included | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning Brush | Operating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing. | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Optional | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.5μm (4-20mA Output) for continuous trouble-free operation.
With a minimum sensitivity range of 0.5 μm and flow rate of 100 mL/min, the Remote Liquid Particle Counter 0.5μm provides real-time continuous data collection at a cost-effective price per point.
This compact liquid particle counter provides versatile mounting options and can be installed where space is at a premium.
The Remote Liquid Particle Counter 0.5μm integrates seamlessly into large facility monitoring and management systems using 4-20mA output.
Features:
• 0.1 – 1.0 μm particle size ranges
• 100 mL/min flow Rate
• 0.3 – 3.0 μm particle size ranges
• 100 mL/min flow Rate
• 0.1 – 1.0 μm particle size ranges
• 100 mL/min flow Rate
• 0.5– 100 μm particle size ranges
• 100 mL/min flow Rate
SERVICE & CALIBRATION