LPC 0.1 μm (MODBUS) | LPC 0.1 µm (4-20mA) | LPC 0.2 μm (MODBUS) | LPC 0.2 μm (4-20mA) | LPC 0.3 μm (MODBUS) | LPC 0.3 μm (4-20mA) | LPC 0.5 μm (MODBUS) | LPC 0.5 μm (4-20mA) | |
Specifications |
||||||||
Size Range | 0.1 – 0.5 µm | 0.1 – 0.5 µm | 0.2 – 2.0 µm | 0.2 –2.0 µm | 0.3 – 3.0 µm | 0.3 – 3.0 µm | 0.5 – 100.0 µm | 0.5 – 100.0 µm |
Channel Sizes | Standard: 0.1, 0.2, 0.3, 0.5 µm | Standard: 0.1, 0.2μm; Optional: 0.1, 0.3µm; 0.1, 0.5µm |
Standard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μm | Standard: 0.2, 0.3μm Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μm |
Standard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μm | Standard: 0.3, 0.5μm Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm |
Standard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μm | Standard: 0.5, 1.0μm Optional: 0.5, 2.0μm; 0.5, 5.0μm |
Laser Source | Laser Diode | |||||||
Flow Rate | 100ml/min | |||||||
Calibration | NIST Traceable | |||||||
Data Storage | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - |
Communication Modes | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA |
LED Indicators | Power, Service, Sampling | Power and Service | Power, Service, Sampling | Power, Service | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling |
Supporting Software | LMS Express, Express RT and RT+, LMSNet | |||||||
Concentration Limit | 64,000 counts/ml @ 5% Coincidence Error | 4,000 counts/ml @ 5% Coincidence Error | ||||||
External Alarm Output | Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp | |||||||
Enclosure | Stainless Steel | |||||||
Sample Inlet/Outlet Connection | 1/4" Flaretek™ | |||||||
Sample Temperature | 32 - 302°F (0 – 150 °C) | |||||||
Sample Pressure | 150 PSI | |||||||
Wetted Surface Materials | Quartz, PTFE, PFA | |||||||
Power | 24V DC | |||||||
Dimensions | 5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm] | |||||||
Weight | 3.5 lbs (1.58 kg) | |||||||
Environmental Conditions |
||||||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | |||||||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing | |||||||
Accessories |
||||||||
Included | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning Brush | Operating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing. | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Optional | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
Our comprehensive line of Remote Liquid Particle Counters will provide you the continuous monitoring data you are looking for. Our Remote Liquid Particle Counters will help you determine the DI Water being supplied to your process always maintains a certain level of cleanliness. These units can be easily setup into Facility Monitoring Systems and can also be easily cleaned and maintained.
Key Features:
Communication Output Options:
Key Features:
Communication Output Options:
Key Features:
Communication Output Options:
Key Features:
Communication Output Options:
Key Features:
Aanmelden voor onze nieuwsbrief
Blijf op de hoogte van alle ontwikkelingen.
SERVICE & CALIBRATION